Who Should Not Take NovoLog® Mix 70/30?

Do not allow children to put small parts in their mouth. This product contains small parts and may pose a choking hazard. Insulin pumps: An insulin pump is a small computerized device that delivers insulin in a steady, continuous dose (basal) and/or a small surge (bolus) at your prompting. Sometimes, you just hit the wrong spot with your syringe or pen needle, and it creates a small bruise. If the pump is dropped, hit against a hard object, or otherwise damaged, the waterproof characteristics of the outer casing of the pump may be compromised. At the time of manufacture and when the reservoir and tubing are properly inserted, your pump is waterproof. Consult your physician for help in determining which insulin types, and in what combinations, are right for you. At Baptist Health, we provide care and education for people with diabetes, including education on insulin, giving insulin shots, demonstrating alternative insulin delivery devices (pumps, pods, pens), and medication management help, empowering them to live their best lives. • If you get alternative site blood glucose results that do not agree with how you feel. • If in doubt, simpatch dexcom g6 change the infusion set because the soft cannula may be dislodged, crimped and/or partially clogged.

Although the pump has multiple safety alarms, it cannot notify you if the infusion set is leaking, or the insulin has lost its potency. Do not leave air in the infusion set. The pump has undergone extensive testing to confirm appropriate operation when used with compatible reservoirs and infusion sets manufactured or distributed by Medtronic Diabetes. Do not use the transmitter adjacent to other electrical equipment which may cause interference with the normal system operation. We cannot guarantee appropriate operation if the pump is used with reservoirs or infusion sets offered by third parties. Ensure that the infusion set is properly in place when the tubing is fully released. Store infusion sets in a cool, dry place. Replace the infusion set if the tape becomes loose, or if the soft cannula becomes fully or partially dislodged from the skin. After clearing the alarm, verify that your pump is set to the correct date and time, and that all other settings are programmed to the desired values. If you are unable to reenter your pump settings, or otherwise believe there is a problem with your pump, contact the 24-Hour Technical Support.

This is a problem unique to PWD who follow other PWD on Share, but it’s making me feel daft and changing the sound would be an upgrade. Test your blood glucose level to make sure the problem is corrected. Always test your blood glucose levels at least four times per day. The higher your blood sugars and HbA1c are, the more at risk you are for developing an infection because those persistently high levels are going to promote the growth of bacteria and impair your immune system. It must not be used on more than one person due to risk of infection. Admelog SoloStar prefilled pens or syringes must never be shared between patients, even if the needle is changed. Admelog should not be used during episodes of hypoglycemia (low blood sugar) or in patients with hypersensitivity to insulin lispro or one of its ingredients. Admelog was approved through an abbreviated approval pathway under the Federal Food, Drug, and Cosmetic Act, called the 505(b)(2) pathway. Reservoir and transfer guard are sterile, non-pyrogenic, and for single use only. Dispose of transfer guard safely in sharps container. Reuse of the infusion set may cause damage to the cannula/needle and lead to infection, site irritation, and/or inaccurate medication delivery.

You may accidentally inject too much medication. Reuse of the reservoir may lead to insulin degradation, infection, inaccurate medication delivery, and/or leaks which may cause damage to the pump. Reservoir and infusion sets For the most current warnings, see the user guide that came with your device. Only use reservoir and infusion sets manufactured or distributed by Medtronic Diabetes. If the infusion site becomes inflamed, replace the set, and use a new site until the first site has healed. Connecting your sensor to a transmitter or recorder that is not approved for use with the sensor may cause damage to the components or inaccurate sensor glucose values. Do not expose your transmitter to MRI equipment, diathermy devices, or other devices that generate strong magnetic fields. Do not expose your pump to MRI equipment, diathermy devices, or other devices that generate strong magnetic fields (for example, x-ray, CT scan, or other types of radiation). These types of insulin products can also be used in insulin pumps to meet both background insulin needs as well as mealtime insulin needs. Do not mix NovoLog® Mix 70/30 with other insulin products or use in an insulin pump.

Das könnte dich auch interessieren …